Chicony Information
Chicony building asking rent and related costs
|
GREEN BUILDING FEATURES |
|
|---|---|
|
Location |
No. 69, Section 2, Guangfu Road, Sanchong District, New Taipei City Base area: 12,357.28 square meters |
|
Base area |
12,357.28 square meters |
|
Floor plan |
39 floors above ground / 4 floors underground |
|
Total floor area |
29,783.6 ping |
|
Booking area |
18 floors (4~16 floors) |
|
Parking space |
ramp plane |
|
Building structure |
above ground SS, underground SRC Use partition: B industrial zone |
|
Created by |
Group Optoelectronics Co., Ltd. |
|
Designer |
Sanmen United Architects Chicago, USA GOETTSCH PARTNERS. INC |
|
Manufacturing company |
Lijin Engineering Co., Ltd. |
|
EQUIPMENT SPECIFICATIONS |
|
|---|---|
|
Total number of floors |
39 F / B4 |
|
Rental floor |
13th floor (4F-16F) |
|
Indoor number of pings available |
About 344 pings (available area of 362 pings) |
|
Public setting ratio (actual conversion of the number of flats) |
About 38% |
|
Building structure |
SS pure steel bone |
|
Indoor net height |
About 2.85 M |
|
Exterior wall |
Glass curtain wall |
|
Elevated floor load |
300kg/m2 |
|
Paid facility |
International conference hall, restaurant, swimming pool, gym |
|
Landscape park |
About 4,000 pings (including donation park) |
|
Electrical Equipment |
High voltage 22.8KV Taipower double feeder power supply |
|
Transformer capacity |
7,750KW |
|
Generator |
Diesel generator 2,000KW*2 |
|
Intelligent device |
BA (Building Automation), CA (Communication Automation),OA (Office Automation) and Security System |
|
Sanitary equipment |
TOTO Japan Toto (free toilet) |
|
Fire Equipment |
Fire hydrant, automatic watering, foam system |
|
Air conditioning equipment |
Central air conditioning 1400RT, ice storage system 7600RT-HR, Information room 24hr independent cooling water system |
|
Elevator equipment |
Germany Thyssen label 13 passenger elevators, 3 freight elevators |
|
Refuge ladder equipment |
B4-RF X 2 Block / B3-1F X 1 Block |
-
電梯平面圖
|
ELEVATOR CONFIGURATION |
||
|---|---|---|
|
Elevator number |
Arrival floor |
Use |
|
#1-3 |
B4-B1, 1F |
Basement conversion passenger elevator |
|
#4-6 |
1F-17F |
Low-rise passenger elevator |
|
#7 |
1F-17F |
Low-level passenger freight elevator (and accessibility) |
|
#8,9 |
B4F-17F |
Low-rise passenger and freight elevator |
|
#10 |
B4F-39F, RF |
High-rise passenger freight elevator (emergency and no obstaclehinder) |
|
#11-16 |
1F, 17F-39F |
High-rise passenger elevator |